Hancor Homepage Hancor Technology Innovation Solutions
 

Storm-PURE™ Catch Basin Inserts

Phase II of EPA's National Pollution Discharge Elimination System (NPDES) requires all but the smallest municipal and industrial storm sewer systems to treat storm water discharge to the "maximum extent practicable". The Storm-PURE catch basin insert, a two-stage unit that will fit into new or existing catch basins, stands apart from competitive units in its ability to remove suspended solids, hydrocarbons and other pollutants.

The upper section consists of a perforated metal catch basket covered by a geotextile filter bag. This assembly captures sediment and debris while allowing filtered water to pass freely down through the center cone. The lower stage contains a patented Mycelx® filter insert that attracts and holds tiny particles of hydrocarbons and oil-bound pollutants. The specially treated adsorbent material instantly bonds contaminant particles, resulting in a 95.0% removal rate of total petroleum hydrocarbons.

Both stages are housed in a corrosion-resistant high density polyethylene body with overflow slots at the top to act as a bypass in unusually high flow conditions. The complete assembly will pass 230 gpm without bypassing the flow.

Unmatched Pollutant Removal

The Storm-PURE water treatment insert stands apart from competitive units in its ability to remove suspended solids, hydrocarbons and other pollutants. In a laboratory test, polluted storm water was processed through the unit, and samples of the influent and effluent were analyzed by Analytical Environmental Services, Inc. to determine removal efficiency. The results are shown in the table below:

Pollutant Removal Performance

Analyzed Components Unit Reporting Limit Influent Effluent Removal
Total Suspended Solids (TSS) mg/L 5 36 11 69.44%
Total Petroleum Hydrocarbons (TPH) mg/L 5 96.9 BRL 99.90%
*Chemical Oxygen Demand (COD) mg/L 10 156 BRL 94.23%
*Nitrogen mg/L 0.2 1.49 BRL 99.33%
*Total Phosphorus mg/L 0.25 19.7 12.8 35.03%
*Iron ug/L 100 1490 362 75.70%
*Copper ug/L 5 86.2 11.5 86.66%
*Lead ug/L 1 1110 106 90.45%
*Zinc ug/L 10 6060 286 95.28%

*Removal related to the components bonding with hydrocarbon molecules.
BRL = Below Reporting Limit

Storm-PURE Specifications

Max. Flow Rate of Filter
(at 0 ft. of head weir flow)
230 gpm (0.52 cfs)
Max. Flow Rate of Bypass
(at 0.5 ft. of head orifice flow)
1189 gpm (2.65 cfs)
Max. Flow Rate of Filter and Bypass
(at 0.5 ft. of head orifice flow)
1419 gpm (3.16 cfs)
Primary Filter (Upper Section)
Sediment/Debris Storage Capacity
1.42 cu ft (170 lbs)
Sediment/Debris Particle Size
Captured by Primary Filter
>0.033 in (838 micron)
Sediment/Debris Particle Size
Captured by Secondary (Mycelx) Filter
>0.012 in (300 micron)
Secondary Filter Hydrocarbon
Removal Storage Capacity
15 lbs (2.04 gal)
Secondary Filter Media Volume 1.60 cu ft
Nyloplast Storm-PURE™ Catch Basin Inserts
 