Table 2-9 – Maximum Cover(1) for Hancor Sure-Lok and Hi-Q Pipe, ft.

 

Class I

Class II

Class III

Diameter

compacted

uncompacted

95%

90%

85%

95%

90%

85%

4

70

24

45

31

24

32

24

22

6

66

21

42

29

21

27

22

20

8

60

19

38

26

19

24

20

17

10

56

17

35

24

17

26

18

15

12

59

18

37

25

18

25

19

17

15

57

17

36

24

17

23

18

16

18

54

16

34

23

16

23

17

14

24

52

15

33

22

15

22

16

13

30

51

14

32

21

14

22

15

13

36

48

12

30

20

12

20

14

11

42

47

12

30

19

12

20

13

11

48

44

11

28

18

11

19

12

10

54

44

11

28

18

11

18

12

10

60

44

11

28

18

11

19

12

10

Notes:
1. Calculations assume no hydrostatic pressure and a density of 120 pcf (1926 kg/m3) for overburden material.