Or, in metric units:
Û |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
WC |
= |
soil column load, N/linearmm of pipe |
|
H |
= |
burial depth, m |
| g s | = |
soil density, kg/m3 |
|
OD |
= |
outside diameter of pipe,mm (Table 2-1 or 2-2) |
The soil arch load (WA) more closely represents the actual soil load experienced by a pipe. The arch load calculation uses a vertical arching factor (VAF) to reduce the earth load in order to account for the support provided by adjacent soil columns. The soil arch load must be used to determine wall thrust.
The arch load is determined using the procedure described below.
First, the geostatic load is calculated by determining the weight of soil directly above the outside diameter of the pipe plus a small triangular load extending just beyond the outside diameter. The equation for the geostatic load, Psp, is shown in Equation 2-2 and 2-2(a).
Equation 2-2
Where:
|
Psp |
= |
geostatic load, psi |
|
H |
= |
burial depth, ft. |
| g s | = |
unit weight of soil, pcf |
|
OD |
= |
outside diameter of pipe, in. (Table 2-1 or 2-2) |
Where:
|
Psp |
= |
geostatic load, N/m2 |
|
H |
= |
burial depth, m |
| g s | = |
unit weight of soil, kg/m3 |
|
OD |
= |
outside diameter of pipe,mm (Table 2-1 or 2-2) |
Next, the vertical arching factor (VAF) must be determined. This factor accounts for the support provided by adjacent soil columns by reducing the geostatic load. The vertical arching factor is computed as shown in Equation 2-3 or 2-3(a).
Where:
|
VAF |
= |
vertical arching factor, unitless |
|
Sh |
= |
hoop stiffness factor; |
|
|
= |
f s MS R / (E A) |
|
f s |
= |
capacity modification factor for soil, 0.9 |
|
MS |
= |
secant constrained soil modulus, psi (Table 2-4) |
|
R |
= |
effective radius of pipe, in. |
|
|
= |
ID/2+c |
|
ID |
= |
inside diameter of pipe, in. (Table 2-1 or 2-2) |
|
c |
= |
distance from inside diameter to neutral axis, in. (Table 2-1 or 2-2) |
|
E |
= |
modulus of elasticity of polyethylene |
|
|
= |
110,000 psi for short term conditions |
|
|
= |
22,000 psi for long term conditions |
|
A |
= |
section area, in2/in (Table 2-1 or Table 2-2) |
Where:
|
VAF |
= |
vertical arching factor, unitless |
|
Sh |
= |
hoop stiffness factor; |
|
|
= |
f s MS R / (E A) |
|
f s |
= |
capacity modification factor for soil, 0.9 |
|
MS |
= |
secant constrained soil modulus, kPa (Table 2-4) |
|
R |
= |
effective radius of pipe,mm |
|
|
= |
ID/2+c |
|
ID |
= |
inside diameter of pipe,mm (Table 2-1 or 2-2) |
|
c |
= |
distance from inside diameter to neutral axis,mm (Table 2-1 or 2-2) |
|
E |
= |
modulus of elasticity of polyethylene |
|
|
= |
758,500 kPa for short term conditions |
|
|
= |
151,700 kPa for long term conditions |
|
A |
= |
section area,mm2/mm (Table 2-1 or 2-2) |
After the geostatic load, Psp, and the VAF have been determined the soil arch load can be found as shown in Equation 2-4 or 2-4(a).
Where:
|
WA |
= |
soil arch load, psi |
|
Psp |
= |
geostatic load, psi |
|
VAF |
= |
vertical arching factor, unitless |
Where:
|
WA |
= |
soil arch load, N/m2 |
|
Psp |
= |
geostatic load, N/m2 |
|
VAF |
= |
vertical arching factor |
The pressure of groundwater must also be accounted for only if present at or above the pipe springline. Equations 2-5 and 2-5(a) provide the method to calculate hydrostatic pressure.
Where:
|
PW |
= |
hydrostatic pressure at springline of pipe, psi |
|
g w |
= |
unit weight of water, 62.4 pcf |
|
Hg |
= |
height of groundwater above springline of pipe, ft. |
Where:
|
PW |
= |
hydrostatic pressure at springline of pipe, N/m2 |
|
g w |
= |
unit weight of water, 1000 kg/m3 |
|
Hg |
= |
height of groundwater above springline of pipe, m |
Some pipe installations are beneath or near foundations. This load contribution must be added to the soil column load before proceeding with the design process. Soil mechanics textbooks include procedures to determine the effect of foundation loads some distance away from the point of application.